Picture of David Robinson

David Robinson

When Your Smart Door Stops Being Smart?

Electronic access control has made building management much easier. It can manage thousands of users, restrict access to individual areas and save building managers an enormous amount of time issuing keys and changing locks. But what happens when the power fails, a reader stops working or the system loses its network connection? Will the doors remain locked, release automatically or keep operating normally?

The consequences of electronic access control failure depend on the equipment and the system’s design. For anyone specifying electronic access control, understanding what happens when something goes wrong is just as important as knowing what the system can do when it works properly.

Electronic access control failure: locked out or locked in?

Not all access control failures have the same consequences. A reader that stops recognising cards might prevent people from entering a building, while a power failure could affect several doors at once. If the system relies on a central server or cloud platform, a loss of connectivity may interfere with some functions without necessarily stopping the doors from operating.

Many systems can continue checking credentials locally, even when they lose communication with the central management platform. Others have battery backup to keep essential equipment operating during a power cut. What happens depends on the equipment and how the installer has configured it, so it’s worth asking some fairly pointed questions before approving a specification.

Will the doors keep recognising existing credentials? Can the building manager still change access permissions? What happens if a reader fails? And, perhaps most importantly, can people still get out?

Fail-safe and fail-secure locking explained

This brings us to two terms that can be confusing: fail-safe and fail-secure. A fail-safe electric locking device releases when its power supply is removed. A fail-secure device remains locked against entry when power is removed. That sounds straightforward enough, but neither description tells you everything about how the complete door will operate.

For example, a door may need to remain secure against entry from outside while allowing people to leave freely from inside. Suitable hardware can achieve this, but the locking arrangement must be designed around the door’s function rather than simply choosing whichever product sounds more secure.

The distinction becomes particularly important on escape routes. Nobody wants to discover during an emergency that an electronic access control failure has prevented people from leaving the building.

Fire doors add another complication

Fire doors already have quite enough to do without introducing electronic equipment that interferes with their performance. Depending on the application, a fire-resisting door may need to remain closed and latched to resist the spread of fire and smoke, while allowing people to escape safely. Adding electronic locking, access readers or automatic operation means considering how those components will work with the existing hardware and what happens if something fails.

A fire alarm interface may be part of the arrangement, but you shouldn’t assume every electronically controlled door needs to unlock in the same way. The requirements depend on the door’s location, function and locking system. Approved Document B provides guidance on electrically powered locks on escape routes in buildings in England, which should be considered alongside the building’s fire strategy and applicable requirements.

Fire performance evidence is also a concern. Cutting into a fire door to install an electronic lock, or introducing cables and other components, can affect the doorset’s performance. The specification needs to establish that the proposed hardware and installation are supported by appropriate evidence.

This is where early involvement from an architectural ironmongery specialist can save a considerable amount of trouble. It’s much easier to define what the door needs to do and select compatible hardware during design than to discover a problem once the doors are on site.

The problems that appear five years later

Power cuts and faulty readers are relatively easy to imagine. Longer-term problems can be much less obvious. Commercial buildings often remain in use for decades, but electronic access systems have a different lifespan. Software platforms change, manufacturers introduce new products and older equipment eventually becomes difficult to maintain. A system that works perfectly well when a building opens may become a headache years later if the manufacturer stops supporting it or replacement components disappear.

This can be particularly awkward when electronic hardware is integrated into the door. Replacing a reader or controller may be relatively straightforward, but changing an obsolete locking mechanism could involve alterations to the doorset, with implications for its performance and certification.

Building owners should therefore ask about replacement parts, software support and future upgrades before committing to a system. It’s also worth establishing whether the installation can accommodate newer equipment without substantial changes to the doors.

Regular maintenance can help reduce the risk of electronic access control failure. Electronic locks, readers, door operators and the mechanical hardware they work alongside all need attention. A fault in a door’s locking mechanism won’t necessarily show up in the access management software, no matter how sophisticated the system is.

Smart enough to cope when things go wrong

None of this should deter specifiers from choosing electronic access control. In many buildings, the flexibility and control it provides make it a far better option than managing hundreds of mechanical keys. The technology is well established, and properly designed installations can operate reliably for years.

But there’s a difference between choosing a system because it offers an impressive list of features and choosing one because it will work properly in the building concerned.

That means understanding who needs access, how the doors will operate during normal use and what should happen when equipment fails. It also means considering the mechanical hardware, fire performance, escape arrangements and maintenance requirements alongside the electronics.

Em-B’s access control and architectural ironmongery teams work together to address these requirements during specification, helping designers and contractors select equipment that works with the complete doorset and the wider building.

After all, there’s little point investing in future of door technology that recognises your smartphone, talks to the building management system and keeps a record of everyone who comes and goes if it can’t cope with a power cut.

Frequently asked questions about electronic access control failure

What happens to electronic access control during a power cut?

This depends on the locking devices, system configuration and available battery backup. Some doors may remain secure against entry, while others release automatically. Safe escape must be maintained in accordance with the applicable requirements.

What is the difference between fail-safe and fail-secure locking?

A fail-safe locking device releases when power is removed, while a fail-secure device remains locked against entry. Neither term alone establishes whether people can escape through the door. This depends on the complete locking arrangement and associated hardware.

Does electronic access control work without an internet connection?

Some electronic access control systems can continue validating existing credentials locally without an internet connection, although remote management and changes to access permissions may be affected. The extent of offline functionality depends on the system and its configuration.

Can electronic access control be fitted to fire doors?

Yes, provided the hardware, installation and any necessary modifications are supported by appropriate fire performance evidence and the arrangement satisfies the door’s fire safety and escape requirements.

People walking through an automatic glazed swing door with an overhead door operator in a commercial building.
Automatic doors and electronic access control systems need to operate safely and reliably, even when equipment fails or power is lost.

LATEST POSTS